Sutopo, Ahmad Analisis susut energi akibat pembebanan tidak seimbang dengan menggunakan inovasi MPR (mengurangi susut teknis dari penyambungan rumah) guna menurunkan arus netral trafo distribusi 20 kV di PT PLN (Persero) ULP Blangpidie UIW Aceh.
AHMAD SUTOPO.pdf
Download (8MB)
Abstract
ABSTRACT
PT PLN (Persero) ULP Blangpidie is a unit in the Aceh Region with aon Power Loss of 4-7%. Factors that cause Losses include loss of electrical energy due to imbalance of the use of unbalanced electricity loads in each phase. One of the decreasing programs to overcome this problem is to use MPR (Reducing on Power Loss From Customer Connection) on New Customer conection, with more customers and increasing kWH sales growth. It is very important in controlling the Losses from balancing the transformer load. Analysis results from 10 samples of distribution transformers 20 kV in ULP Blangpidie Kantor feeders found a decrease in transformer load imbalance >30% which previously amounted to 3 transformers to 1 transformer and a reduction or saving of 18,612 kWh during peak load.
Key Words: Distribution transformer 20 kV, Losses, MPR, Saving kWh, Load Balancing